Changing a quartz watch battery is a small job with a few ways to cause damage. A rushed case opening can scratch the case, bend the stem or break the gasket that keeps water out. This guide covers the whole process, from checking the watch to closing the back. For how often a cell lasts, see how long a watch battery lasts.
Check that your watch is battery-powered
Many quartz watches say “Quartz” on the dial or caseback, but not all of them do. If you’re unsure, check the manual or the brand’s product listing. Mechanical and automatic watches have no battery at all. They run on a mainspring, so a stopped one needs winding (or wearing, for an automatic) or servicing, not a new cell.
What you will need
- A replacement cell that matches the code on the old one (see the table below)
- Plastic or other non-metal tweezers. Metal tweezers can short the cell’s terminals.
- A tool to open the case back: a thin blade, a case back wrench, or a rubber friction ball, depending on the back type
- A small precision screwdriver, if the back is held by screws
- A soft cloth or mouse mat to protect the dial and crystal
- A small dish or tray for screws and parts
- Optional: a watch battery tester, and a case press for closing the back
Step 1: Confirm the battery is the problem
A second hand that jumps instead of ticking, a dead digital display, or a watch that has stopped can all point to a flat cell. A stopped watch can have other causes, though. Make sure the crown is fully pushed in, because a crown pulled out to the setting position stops many quartz movements. A battery tester that puts a load on the cell is a more reliable check than a meter reading. If you can’t test the cell yourself, a shop can check it.
For more on the warning signs, see signs your watch battery is dying.
Step 2: Open the case back
Work on a soft surface with the watch face-down on a cloth. Identify the back type first, then use the matching tool.
- Snap-on: a smooth back with a small notch or lip along the edge. Use a thin, non-marking blade in the notch and lever gently.
- Screw-down: a round back with small notches around the outside. Use a case back wrench or a friction ball, and turn counter-clockwise.
- Screwed-plate: a flat back held by tiny screws. Use a fine screwdriver that fits the screw heads exactly.
The full method is in how to open and close a watch case back. For a quicker guide to identifying the back type, see how do I open my watch to replace the battery.
Step 3: Note the battery code and remove the old cell
Before you lift anything out, read the code printed on the cell and note how it sits: which side faces up, and which clip or arm holds it. A photo helps.
Slide or lift the cell out with plastic tweezers. Some cells sit under a metal arm or strap. Move the arm only as far as you need.
Common silver oxide codes and their equivalents are below. Check your cell against a current cross-reference chart, because manufacturers don’t always use the same codes.
| Code on cell | Equivalent | Nominal voltage |
|---|---|---|
| 377 | SR626SW | 1.55 V |
| 371 | SR920SW | 1.55 V |
| 364 | SR621SW | 1.55 V |
| 362 | SR721SW | 1.55 V |
| 393 | SR754SW | 1.55 V |
Lithium coin cells, often marked CR (such as CR2016 or CR2025), are 3 V and use a different chemistry. Use only the cell type the watch is built for.
Step 4: Fit the new cell
Put the new cell in the same way the old one came out. The positive side, usually the flat side with the printing, should face the same way. Slide or press it under the retaining clip or arm until it sits flat and is held firmly.
Check the watch before you close the case. The second hand should start ticking, or the display should come on. If the watch doesn’t start, check that the cell is seated and the crown is pushed in, then set the time.
Step 5: Close the case back and test
Line up the back with its notch, and check that the gasket is clean and seated in its groove. Press the back on evenly, or use a case press with the right dies. Don’t force it. Start screw-down backs by hand, then tighten them with the wrench, to avoid cross-threading. The closing steps are in the case back guide.
Then check that the time keeps running over the next day or two.
Can you change a watch battery without tools?
Sometimes, but the risk depends on the back.
- Snap-on backs can sometimes be opened with a thin, non-metal tool. The blade can slip, though, and scratch the case or damage the gasket.
- Screw-down backs usually need a case back wrench or a rubber friction ball. Some guides suggest the tips of scissors in two opposite notches. This can work, but the tips slip easily and mark the back.
- Screwed-plate backs need a precision screwdriver. Household screwdrivers are usually too large to fit the tiny screw heads.
“No tools” means accepting more risk to the case and the seal. If the watch is valuable, water-resistant, or hard to open, a jeweller is the safer option.
Olivia Burton and other fashion watches
Many fashion quartz watches use small silver oxide cells, and some brands use case backs that are fiddly to open. Read the code on the old cell rather than relying on a size guess from a listing or a video, because those aren’t always accurate for a specific model.
If you own an Olivia Burton watch, the brand’s manual or customer service team is the best source for the correct cell and case back type. Some new watches also have a plastic tab under the battery to stop it draining while stored. If a new watch won’t start, check for one before you buy a new cell. Opening a watch yourself may affect any warranty, so check the terms first.
When to take it to a jeweller or watchmaker
- You’re not sure which case back type you have, or the back won’t move with the right tool
- The watch is valuable, rare, or has sentimental value
- The watch is water-resistant and you want its seal checked
- The watch stops again soon after the change, which can point to a movement fault
- You see moisture, condensation or a cracked crystal (see how to replace a watch crystal)
For what a shop may charge, see how much Timpson charge to change a watch battery.
Opening the case disturbs the gasket. If the watch is meant to be water-resistant, have the seal checked before you swim or shower in it. Closing the back by itself doesn’t confirm the watch is still sealed.